Search in Category
Filter Your Search
Shop by Category
Fuses
L TD FUSE 600V 400A A4BQ
Recommended for Arc Flash energy reduction; Metal-embossed date and catalog number for traceability and lasting identification; Feeders; Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts”; Most current-limiting for lowest peak let-thru current; even at fault currents up to 300kA; Mains; 300kA interrupting rating – self-certified, UL witnessed tests; Pure silver links ensure lowest let-thru current and longer fuse life; Circuit breaker back-up; Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse; Time-delay for high inrush loads such as motors and transformers, without nuisance opening; High-visibility orange label gives instant brand recognition; High-grade silica filler ensures fast arc quenching; UL listed; Fiberglass body provides dimensional stability in harsh industrial settings; Rejection-style design prevents replacement errors; Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator; DC listed to UL standard 248 (100-2000A); CSA certified to standard C22.2 No. 248.10 (601-6000A); Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service; UL listed to standard 248-10 File E2137; Large motors; Lighting, heating & general loads
600V 450A L TD FUSE
Mains; Fiberglass body provides dimensional stability in harsh industrial settings; Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service; DC listed to UL standard 248 (100-2000A); Feeders; UL listed; Most current-limiting for lowest peak let-thru current; even at fault currents up to 300kA; Circuit breaker back-up; Rejection-style design prevents replacement errors; Lighting, heating & general loads; Pure silver links ensure lowest let-thru current and longer fuse life; High-grade silica filler ensures fast arc quenching; High-visibility orange label gives instant brand recognition; UL listed to standard 248-10 File E2137; Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator; Metal-embossed date and catalog number for traceability and lasting identification; Large motors; CSA certified to standard C22.2 No. 248.10 (601-6000A); Time-delay for high inrush loads such as motors and transformers, without nuisance opening; 300kA interrupting rating – self-certified, UL witnessed tests; Recommended for Arc Flash energy reduction; Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts”; Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse
L TD FUSE 600V 600A A4BQ
High-visibility orange label gives instant brand recognition; UL listed to standard 248-10 File E2137; 300kA interrupting rating – self-certified, UL witnessed tests; Large motors; Mains; Feeders; Rejection-style design prevents replacement errors; Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse; Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service; Recommended for Arc Flash energy reduction; Most current-limiting for lowest peak let-thru current; even at fault currents up to 300kA; High-grade silica filler ensures fast arc quenching; CSA certified to standard C22.2 No. 248.10 (601-6000A); Fiberglass body provides dimensional stability in harsh industrial settings; Lighting, heating & general loads; Circuit breaker back-up; Pure silver links ensure lowest let-thru current and longer fuse life; Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts”; UL listed; DC listed to UL standard 248 (100-2000A); Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator; Time-delay for high inrush loads such as motors and transformers, without nuisance opening; Metal-embossed date and catalog number for traceability and lasting identification