Search in Category
Search Filters
-
0.9 lb x
Filter Your Search
Shop by Category
Fuses
250V 125A 7 1/8x1 9/10 TD
Branch circuits; Feeders; Mains; Transformers; Metal-embossed date and catalog number for traceability and lasting identification; CSA certified to standard C22.2 no. 248.12; Service entrance equipment; UL listed to standard 248-12 File E2137; Current-limiting; Current-limiting for low peak let-thru current; Optional solid state SmartSpot blown fuse indicator; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Motor circuits; Easy-to-read label for quick brand recognition and replacement; DC listed to UL standard 248 TRS only; Fiberglass body provides dimensional stability in harsh industrial settings; High-grade silica filler ensures fast arc quenching and high current limitation; Time-delay; AC & DC rated; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; General-purpose equipment
250V 125A TD RK5 FUSE SMARTSPO
Transformers; AC & DC rated; Time-delay; Fiberglass body provides dimensional stability in harsh industrial settings; DC listed to UL standard 248 TRS only; Feeders; Optional solid state SmartSpot blown fuse indicator; Metal-embossed date and catalog number for traceability and lasting identification; CSA certified to standard C22.2 no. 248.12; Easy-to-read label for quick brand recognition and replacement; Mains; Motor circuits; Service entrance equipment; Current-limiting; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); General-purpose equipment; Branch circuits; Current-limiting for low peak let-thru current; UL listed to standard 248-12 File E2137; High-grade silica filler ensures fast arc quenching and high current limitation; Time-delay for motor start-ups and transformer inrush currents without nuisance opening
250V 200A 7 1/8x1 9/10 TD
Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Optional solid state SmartSpot blown fuse indicator; Mains; DC listed to UL standard 248 TRS only; Easy-to-read label for quick brand recognition and replacement; CSA certified to standard C22.2 no. 248.12; Service entrance equipment; UL listed to standard 248-12 File E2137; Fiberglass body provides dimensional stability in harsh industrial settings; Time-delay; Metal-embossed date and catalog number for traceability and lasting identification; Current-limiting for low peak let-thru current; Transformers; General-purpose equipment; Current-limiting; Feeders; Motor circuits; High-grade silica filler ensures fast arc quenching and high current limitation; AC & DC rated; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Branch circuits
250V 200A TD RK5 FUSE SMARTSPO
Current-limiting; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; AC & DC rated; Easy-to-read label for quick brand recognition and replacement; Motor circuits; High-grade silica filler ensures fast arc quenching and high current limitation; Branch circuits; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Feeders; Metal-embossed date and catalog number for traceability and lasting identification; General-purpose equipment; Optional solid state SmartSpot blown fuse indicator; Transformers; Fiberglass body provides dimensional stability in harsh industrial settings; Service entrance equipment; CSA certified to standard C22.2 no. 248.12; UL listed to standard 248-12 File E2137; Mains; DC listed to UL standard 248 TRS only; Time-delay; Current-limiting for low peak let-thru current