Fuses
CC TD FUSE 600V 3A ATQR
Inductive loads; High-grade silica filler ensures fast arc quenching and high current limitation; DC listed to UL standard 248; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Control transformers; High visibility orange label ensures instant brand recognition, and simplifies replacement; UL listed to standard 248-4 File E2137; Time-delay for control transformer inrush loads without nuisance opening; Lighting, heating & general-purpose loads; CSA certified to standard C22.2 No. 248.4; Highly current-limiting for low peak let-thru current; Metal-embossed date and catalog number for traceability and lasting identification; Fiberglass body provides dimensional stability in harsh industrial settings; Solenoids
J TD FUSE 600V 40A AJT
Lighting, heating & general loads; Metal-embossed date and catalog number for traceability and lasting identification; Time-delay for motor starting and transformer inrush; High-grade silica filler ensures fast arc quenching; Bus duct; UL listed; Unique Class J dimensions prevent replacement errors; Non-indicating or solid state SmartSpot visual blown fuse indicator; High-visibility orange label gives instant brand recognition; Feeders; 300kA interrupting rating – self-certified, UL witnessed tests; Motor circuits; Circuit breaker back-up; Extremely current-limiting for low peak let-thru current; Mains; Control panels; Transformers; Fiberglass body provides dimensional stability in harsh industrial settings; DC listed to UL standard 248; Recommended for Arc Flash energy reduction; UL listed to standard 248-8 File E2137; Branch circuits; Load centers; Most current-limiting UL class fuse; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; IEC 60269-2-1; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; DC tested to UL standard 248; CSA certified to standard C22.2 No. 248.8; Small footprint requires less mounting space and allows smaller, more economical fuse blocks
600V 400A CLASS J TD FUSE
IEC 60269-2-1; UL listed; High-grade silica filler ensures fast arc quenching; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; High-visibility orange label gives instant brand recognition; Motor circuits; Control panels; Metal-embossed date and catalog number for traceability and lasting identification; Unique Class J dimensions prevent replacement errors; DC tested to UL standard 248; UL listed to standard 248-8 File E2137; Load centers; DC listed to UL standard 248; Transformers; Mains; Feeders; Extremely current-limiting for low peak let-thru current; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; 300kA interrupting rating – self-certified, UL witnessed tests; Lighting, heating & general loads; Fiberglass body provides dimensional stability in harsh industrial settings; Circuit breaker back-up; Recommended for Arc Flash energy reduction; Non-indicating or solid state SmartSpot visual blown fuse indicator; Most current-limiting UL class fuse; Bus duct; Branch circuits; CSA certified to standard C22.2 No. 248.8; Time-delay for motor starting and transformer inrush; Small footprint requires less mounting space and allows smaller, more economical fuse blocks
600V 10A CC FUSE
General loads; Lighting; Rejection-style design prevents replacement errors when used with recommended fuse blocks; DC listed to UL Standard 248; Control circuits; CSA Certified to Standard C22.2 No. 248.4; Branch circuit protection; Versatile design for individual component and branch circuit protection; UL Listed to Standard 248-4 File E2137
CC TD FUSE 600V 6-1/4A ATQR
UL listed to standard 248-4 File E2137; Inductive loads; High visibility orange label ensures instant brand recognition, and simplifies replacement; Solenoids; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Highly current-limiting for low peak let-thru current; Time-delay for control transformer inrush loads without nuisance opening; Fiberglass body provides dimensional stability in harsh industrial settings; DC listed to UL standard 248; Metal-embossed date and catalog number for traceability and lasting identification; High-grade silica filler ensures fast arc quenching and high current limitation; Control transformers; Lighting, heating & general-purpose loads; CSA certified to standard C22.2 No. 248.4
FUSE, CLASS J T/D (AJT15)
Most current-limiting UL class fuse; Load centers; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; CSA certified to standard C22.2 No. 248.8; High-grade silica filler ensures fast arc quenching; Circuit breaker back-up; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Lighting, heating & general loads; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Non-indicating or solid state SmartSpot visual blown fuse indicator; 300kA interrupting rating – self-certified, UL witnessed tests; DC tested to UL standard 248; Extremely current-limiting for low peak let-thru current; High-visibility orange label gives instant brand recognition; Branch circuits; Motor circuits; Mains; Feeders; Transformers; Time-delay for motor starting and transformer inrush; Bus duct; Fiberglass body provides dimensional stability in harsh industrial settings; Recommended for Arc Flash energy reduction; Unique Class J dimensions prevent replacement errors; UL listed to standard 248-8 File E2137; Control panels; Metal-embossed date and catalog number for traceability and lasting identification; DC listed to UL standard 248; UL listed; IEC 60269-2-1
250V 25A 2x9/16 RK5 TD FU
Service entrance equipment; Transformers; CSA certified to standard C22.2 no. 248.12; Time-delay; Current-limiting; Optional solid state SmartSpot blown fuse indicator; General-purpose equipment; High-grade silica filler ensures fast arc quenching and high current limitation; Easy-to-read label for quick brand recognition and replacement; Current-limiting for low peak let-thru current; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Mains; Fiberglass body provides dimensional stability in harsh industrial settings; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Branch circuits; Motor circuits; Feeders; Metal-embossed date and catalog number for traceability and lasting identification; UL listed to standard 248-12 File E2137; AC & DC rated; DC listed to UL standard 248 TRS only
600V 30A 3P CC ULTSFE
DIN-rail mounting; CSA Certified C22.2; IP20 Finger-Safe (touch safe); ATM, DCT, ATMR recommended for DC applications; UL Listed to Standard 4248- 4 (class CC) and 4248-1 (midget), File E52283; Compact footprint; UL Listed to standard 4248-18 (photovoltaic), File E347822; IEC 60269-2-1 and 60947-3 Compliant (USM only); Optional visual blown fuse Indicator lights; Quick, tool-free, easy fuse change outs
600V 30A 3P CC ULTSFE W/IND
DIN-rail mounting; ATM, DCT, ATMR recommended for DC applications; CSA Certified C22.2; UL Listed to standard 4248-18 (photovoltaic), File E347822; IP20 Finger-Safe (touch safe); Optional visual blown fuse Indicator lights; IEC 60269-2-1 and 60947-3 Compliant (USM only); Compact footprint; UL Listed to Standard 4248- 4 (class CC) and 4248-1 (midget), File E52283; Quick, tool-free, easy fuse change outs
CC FUSE BLOCK 600V 30A 3P PP
UL listed, guide IZLT, File E52283; CSA certified class 6225, File 32169