Fuses
SPD T2,40kA,Uc150V,1+1 TT,2P,
Reversible chassis to allow cable entry from above or below; DIN-rail mountable, plug-in format; IEC 61643-11; UL 1449 4th Ed.; TNS, TNC, TT and IT networks; Visual and remote end of life indicators; Mechanically coded cartridges to avoid cartridge replacement errors; EN 61643-11
SPD T2,40kA,Uc150V,1+1 TT,2P,
DIN-rail mountable, plug-in format; IEC 61643-11; EN 61643-11; TNS, TNC, TT and IT networks; UL 1449 4th Ed.; Mechanically coded cartridges to avoid cartridge replacement errors; Reversible chassis to allow cable entry from above or below; Visual and remote end of life indicators
SPD T2,40kA,Uc275V,2+0 TNS,2P,
IEC 61643-11; TNS, TNC, TT and IT networks; EN 61643-11; UL 1449 4th Ed.; DIN-rail mountable, plug-in format; Visual and remote end of life indicators; Reversible chassis to allow cable entry from above or below; Mechanically coded cartridges to avoid cartridge replacement errors
SPD T2,40kA,Ucpv 660V,YPV PV,
Multiple MPPT specific products with UL 1449 certification; IEC 61643-31; UL 1449 4th Ed.; Reversible chassis to allow cable entry from above or below; EN 50539-11; DIN-rail mountable, plug-in format; Visual and remote end of life indicators; Mechanically coded cartridges to avoid cartridge replacement errors
SPD T2,40kA,Ucpv 660V,YPV PV,
DIN-rail mountable, plug-in format; Reversible chassis to allow cable entry from above or below; IEC 61643-31; UL 1449 4th Ed.; Multiple MPPT specific products with UL 1449 certification; Visual and remote end of life indicators; EN 50539-11; Mechanically coded cartridges to avoid cartridge replacement errors
SPD T2,40kA,Ucpv 1060V,YPV PV,
UL 1449 4th Ed.; DIN-rail mountable, plug-in format; Mechanically coded cartridges to avoid cartridge replacement errors; EN 50539-11; Reversible chassis to allow cable entry from above or below; Multiple MPPT specific products with UL 1449 certification; IEC 61643-31; Visual and remote end of life indicators
SPD T2,40kA,Uc440V,3+0,R
Reversible chassis to allow cable entry from above or below; IEC 61643-11; DIN-rail mountable, plug-in format; TNS, TNC, TT and IT networks; Visual and remote end of life indicators; UL 1449 4th Ed.; Mechanically coded cartridges to avoid cartridge replacement errors; EN 61643-11
SPD T1+2,12.5kA,Uc275V,L-N,1P,
Reversible chassis to allow cable entry from above or below; Mechanically coded cartridges to avoid cartridge replacement errors; TNS, TNC, TT and IT networks; IEC 61643-11; EN 61643-11; DIN-rail mountable, plug-in format; Visual and remote end of life indicators
SPD T1+2,12.5kA,Uc320V,
EN 61643-11; DIN-rail mountable, plug-in format; IEC 61643-11; Reversible chassis to allow cable entry from above or below; Visual and remote end of life indicators; TNS, TNC, TT and IT networks; Mechanically coded cartridges to avoid cartridge replacement errors
SPD T2+3,20kA,Uc150V,L-N,1P,
Mechanically coded cartridges to avoid cartridge replacement errors; TNS, TNC, TT and IT networks; DIN-rail mountable, plug-in format; IEC 61643-11; Visual and remote end of life indicators; EN 61643-11; PLC friendly solutions (LCF) for Power Line Communications; Reversible chassis to allow cable entry from above or below