Search in Category
Filter Your Search
Shop by Category
Fuses
250V 50A 3x13/16 RK5 TD F
High-grade silica filler ensures fast arc quenching and high current limitation; Motor circuits; General-purpose equipment; Easy-to-read label for quick brand recognition and replacement; Mains; Metal-embossed date and catalog number for traceability and lasting identification; Current-limiting; Time-delay; Service entrance equipment; Feeders; Current-limiting for low peak let-thru current; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); AC & DC rated; Optional solid state SmartSpot blown fuse indicator; DC listed to UL standard 248 TRS only; UL listed to standard 248-12 File E2137; Branch circuits; Fiberglass body provides dimensional stability in harsh industrial settings; CSA certified to standard C22.2 no. 248.12; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Transformers
250V 35A 3x13/16 RK5 TD F
UL listed to standard 248-12 File E2137; Current-limiting; AC & DC rated; Time-delay; General-purpose equipment; Feeders; Mains; Easy-to-read label for quick brand recognition and replacement; Current-limiting for low peak let-thru current; Service entrance equipment; CSA certified to standard C22.2 no. 248.12; Branch circuits; High-grade silica filler ensures fast arc quenching and high current limitation; DC listed to UL standard 248 TRS only; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Motor circuits; Metal-embossed date and catalog number for traceability and lasting identification; Fiberglass body provides dimensional stability in harsh industrial settings; Optional solid state SmartSpot blown fuse indicator; Transformers
250V 45A 3x13/16 RK5 TD F
Motor circuits; Easy-to-read label for quick brand recognition and replacement; Transformers; AC & DC rated; DC listed to UL standard 248 TRS only; High-grade silica filler ensures fast arc quenching and high current limitation; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Fiberglass body provides dimensional stability in harsh industrial settings; Branch circuits; Current-limiting for low peak let-thru current; CSA certified to standard C22.2 no. 248.12; General-purpose equipment; Optional solid state SmartSpot blown fuse indicator; Time-delay; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Metal-embossed date and catalog number for traceability and lasting identification; UL listed to standard 248-12 File E2137; Mains; Feeders; Current-limiting; Service entrance equipment
250V 35A RK5 3-PACK
General-purpose equipment; CSA certified to standard C22.2 no. 248.12; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Fiberglass body provides dimensional stability in harsh industrial settings; Mains; AC & DC rated; Current-limiting; Optional solid state SmartSpot blown fuse indicator; Metal-embossed date and catalog number for traceability and lasting identification; DC listed to UL standard 248 TRS only; Time-delay; Motor circuits; High-grade silica filler ensures fast arc quenching and high current limitation; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Branch circuits; Easy-to-read label for quick brand recognition and replacement; Transformers; Feeders; UL listed to standard 248-12 File E2137; Current-limiting for low peak let-thru current; Service entrance equipment
250V 35A TD RK5 FUSE SMARTSPOT
Time-delay; Fiberglass body provides dimensional stability in harsh industrial settings; AC & DC rated; Service entrance equipment; Easy-to-read label for quick brand recognition and replacement; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Current-limiting for low peak let-thru current; Branch circuits; High-grade silica filler ensures fast arc quenching and high current limitation; Mains; UL listed to standard 248-12 File E2137; DC listed to UL standard 248 TRS only; Current-limiting; CSA certified to standard C22.2 no. 248.12; Transformers; Motor circuits; Feeders; Optional solid state SmartSpot blown fuse indicator; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; General-purpose equipment; Metal-embossed date and catalog number for traceability and lasting identification
250V 40A TD RK5 FUSE SMARTSPOT
Service entrance equipment; Time-delay; General-purpose equipment; Easy-to-read label for quick brand recognition and replacement; Transformers; Current-limiting for low peak let-thru current; Motor circuits; CSA certified to standard C22.2 no. 248.12; Mains; Current-limiting; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Feeders; High-grade silica filler ensures fast arc quenching and high current limitation; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; AC & DC rated; Metal-embossed date and catalog number for traceability and lasting identification; Optional solid state SmartSpot blown fuse indicator; Branch circuits; DC listed to UL standard 248 TRS only; Fiberglass body provides dimensional stability in harsh industrial settings; UL listed to standard 248-12 File E2137
250V 50A RK5 3-PACK
Optional solid state SmartSpot blown fuse indicator; High-grade silica filler ensures fast arc quenching and high current limitation; Time-delay; Current-limiting for low peak let-thru current; Transformers; General-purpose equipment; Current-limiting; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Fiberglass body provides dimensional stability in harsh industrial settings; Motor circuits; Service entrance equipment; Metal-embossed date and catalog number for traceability and lasting identification; DC listed to UL standard 248 TRS only; Feeders; Easy-to-read label for quick brand recognition and replacement; UL listed to standard 248-12 File E2137; CSA certified to standard C22.2 no. 248.12; Mains; AC & DC rated; Branch circuits; Rejection-style design prevents replacement errors (when used with recommended fuse blocks)