600V 125A RK1 TD FUSE

600V 125A RK1 TD FUSE

Item #: A6D125R

Supplier Part #: A6D125R
Brand: Mersen

Amp-Trap 2000® SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.

UL listed to standard 248-12 File E2137; Disconnects; Metal-embossed date and catalog number for easier traceability and lasting identification; 300kA interrupting rating – self-certified, UL witnessed tests; Fiberglass body provides dimensional stability in harsh industrial settings; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Solid state SmartSpot visual blown fuse indicator; Safety switches; Reduced inventory by taking the place of class RK5, K, and H fuses; DC listed to UL standard 248; 600VAC & 600VDC dual rated; Recommended for Arc Flash energy reduction; Motors; Extremely current-limiting for low peak let-thru current; CSA certified to standard C22.2 No. 248.12; High-visibility orange label gives instant brand recognition; Control panels; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Transformers; Time-delay for motor starting and transformer inrush currents without nuisance opening; Branch circuit protection; All general-purpose circuits

$246.99 /EA
NOT CURRENTLY IN STOCK
600V 150A RK1 TD FUSE

600V 150A RK1 TD FUSE

Item #: A6D150R

Supplier Part #: A6D150R
Brand: Mersen

Amp-Trap 2000® SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.

300kA interrupting rating – self-certified, UL witnessed tests; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Motors; All general-purpose circuits; Safety switches; Fiberglass body provides dimensional stability in harsh industrial settings; Recommended for Arc Flash energy reduction; Transformers; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; 600VAC & 600VDC dual rated; UL listed to standard 248-12 File E2137; Disconnects; Time-delay for motor starting and transformer inrush currents without nuisance opening; Solid state SmartSpot visual blown fuse indicator; Reduced inventory by taking the place of class RK5, K, and H fuses; Branch circuit protection; Control panels; CSA certified to standard C22.2 No. 248.12; Metal-embossed date and catalog number for easier traceability and lasting identification; Extremely current-limiting for low peak let-thru current; High-visibility orange label gives instant brand recognition; DC listed to UL standard 248

$246.99 /EA
NOT CURRENTLY IN STOCK
600V 110A RK1 TD FUSE

600V 110A RK1 TD FUSE

Item #: A6D110R

Supplier Part #: A6D110R
Brand: Mersen

Amp-Trap 2000® SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.

Branch circuit protection; 600VAC & 600VDC dual rated; 300kA interrupting rating – self-certified, UL witnessed tests; Fiberglass body provides dimensional stability in harsh industrial settings; Time-delay for motor starting and transformer inrush currents without nuisance opening; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); CSA certified to standard C22.2 No. 248.12; All general-purpose circuits; Disconnects; Reduced inventory by taking the place of class RK5, K, and H fuses; Transformers; Control panels; Recommended for Arc Flash energy reduction; Safety switches; Extremely current-limiting for low peak let-thru current; High-visibility orange label gives instant brand recognition; Metal-embossed date and catalog number for easier traceability and lasting identification; DC listed to UL standard 248; UL listed to standard 248-12 File E2137; Motors; Solid state SmartSpot visual blown fuse indicator

$246.99 /EA
NOT CURRENTLY IN STOCK
600V 175A RK1 TD FUSE

600V 175A RK1 TD FUSE

Item #: A6D175R

Supplier Part #: A6D175R
Brand: Mersen

Amp-Trap 2000® SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.

Recommended for Arc Flash energy reduction; Motors; UL listed to standard 248-12 File E2137; 300kA interrupting rating – self-certified, UL witnessed tests; All general-purpose circuits; CSA certified to standard C22.2 No. 248.12; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Solid state SmartSpot visual blown fuse indicator; Metal-embossed date and catalog number for easier traceability and lasting identification; Extremely current-limiting for low peak let-thru current; DC listed to UL standard 248; 600VAC & 600VDC dual rated; Reduced inventory by taking the place of class RK5, K, and H fuses; Safety switches; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High-visibility orange label gives instant brand recognition; Control panels; Transformers; Branch circuit protection; Time-delay for motor starting and transformer inrush currents without nuisance opening; Disconnects; Fiberglass body provides dimensional stability in harsh industrial settings

$246.99 /EA
NOT CURRENTLY IN STOCK

600V 200A RK1 TD FUSE

Item #: A6D200R

Supplier Part #: A6D200R
Brand: Mersen

Amp-Trap 2000® SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.

Fiberglass body provides dimensional stability in harsh industrial settings; 600VAC & 600VDC dual rated; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Time-delay for motor starting and transformer inrush currents without nuisance opening; Metal-embossed date and catalog number for easier traceability and lasting identification; DC listed to UL standard 248; Branch circuit protection; Recommended for Arc Flash energy reduction; High-visibility orange label gives instant brand recognition; UL listed to standard 248-12 File E2137; Control panels; Transformers; Solid state SmartSpot visual blown fuse indicator; 300kA interrupting rating – self-certified, UL witnessed tests; All general-purpose circuits; Disconnects; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Extremely current-limiting for low peak let-thru current; CSA certified to standard C22.2 No. 248.12; Reduced inventory by taking the place of class RK5, K, and H fuses; Safety switches; Motors

$246.99 /EA
NOT CURRENTLY IN STOCK