Browse Categories

Search in Category

Fuses

Search Filters

  • NH3 x
  • Hungary x
  • Mersen x

Filter Your Search

Shop by Category

Loading...

Fuses

Power Products/Fuses 
Viewing Page 1 of 7 (63 results)

NH 3C 300A 500V GG

Item #: A212635

Supplier Part #: A212635
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

0% cadmium; IEC 60269-1 and -2; Lead free contact blades; VDE 0636 Part 201; Double indicator; Dimensions according to DIN 43 620 parts 1 to 4; Non-isolated gripping lugs

$183.21 /EA
NOT CURRENTLY IN STOCK
NH 3 315A 690V GG

NH 3 315A 690V GG

Item #: B228506

Supplier Part #: B228506
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

IEC 60269-1 and -2; 0% cadmium; Dimensions according to DIN 43 620 parts 1 to 4; Double indicator; VDE 0636 Part 201; Lead free contact blades; Non-isolated gripping lugs

$190.55 /EA
NOT CURRENTLY IN STOCK
NH 3 355A 690V AM

NH 3 355A 690V AM

Item #: G227982

Supplier Part #: G227982
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Lead free contact blades; Dimensions according to DIN 43 620 parts 1 to 4; IEC 60269-1 and -2; Non-isolated gripping lugs; Double indicator; 0% cadmium; VDE 0636 Part 201

$228.01 /EA
NOT CURRENTLY IN STOCK
NH 3 250A 400V GG SGL

NH 3 250A 400V GG SGL

Item #: J223752

Supplier Part #: J223752
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

IEC 60269-1 and -2; 0% cadmium; Dimensions according to DIN 43 620 Parts 1 to 4; Double indicator; VDE 0636 Part 201; Isolated metal gripping lugs (SGL); Lead free contact blades

$218.29 /EA
NOT CURRENTLY IN STOCK

NH 3 400A 400V GG

Item #: L223754

Supplier Part #: L223754
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

Lead free contact blades; Isolated metal gripping lugs (SGL); IEC 60269-1 and -2; Dimensions according to DIN 43 620 Parts 1 to 4; VDE 0636 Part 201; 0% cadmium; Double indicator

$218.29 /EA
NOT CURRENTLY IN STOCK

NH 3 450A 500V GG

Item #: M217223

Supplier Part #: M217223
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Dimensions according to DIN 43 620 parts 1 to 4; IEC 60269-1 and -2; Lead free contact blades; Double indicator; Non-isolated gripping lugs; 0% cadmium; VDE 0636 Part 201

$183.21 /EA
NOT CURRENTLY IN STOCK
NH 3 500A 400V GG SGL

NH 3 500A 400V GG SGL

Item #: M223755

Supplier Part #: M223755
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

Dimensions according to DIN 43 620 Parts 1 to 4; 0% cadmium; VDE 0636 Part 201; Double indicator; IEC 60269-1 and -2; Lead free contact blades; Isolated metal gripping lugs (SGL)

$218.29 /EA
NOT CURRENTLY IN STOCK

NH 3 630A 500V AM

Item #: M227987

Supplier Part #: M227987
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Lead free contact blades; 0% cadmium; VDE 0636 Part 201; Double indicator; Dimensions according to DIN 43 620 parts 1 to 4; Non-isolated gripping lugs; IEC 60269-1 and -2

$178.19 /EA
NOT CURRENTLY IN STOCK
NH 3 250A 500V GG SGL

NH 3 250A 500V GG SGL

Item #: S211087

Supplier Part #: S211087
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Lead free contact blades; Isolated metal gripping lugs (SGL); VDE 0636 Part 201; 0% cadmium; Double indicator; Dimensions according to DIN 43 620 Parts 1 to 4; IEC 60269-1 and -2

$218.29 /EA
NOT CURRENTLY IN STOCK
NH 3 355A 500V AM

NH 3 355A 500V AM

Item #: S232523

Supplier Part #: S232523
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Non-isolated gripping lugs; 0% cadmium; Double indicator; Lead free contact blades; Dimensions according to DIN 43 620 parts 1 to 4; VDE 0636 Part 201; IEC 60269-1 and -2

$237.01 /EA
NOT CURRENTLY IN STOCK
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • NEXT »