Search in Category
Filter Your Search
Shop by Category
Fuses
H TD FUSE 250V 450A CRN
CSA Certified; Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses
H TD FUSE 250V 500A CRN
Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses; CSA Certified
H TD FUSE 250V 600A CRN
Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses; CSA Certified
250V 450A RK1 FUSE
Load centers; Fiberglass body provides dimensional stability in harsh industrial environments; Switchboards; Self-certified for DC per UL248; Panelboards; Lighting circuits; CSA certified to standard C22.2 No. 248.12; Rejection style design prevents replacement by other fuse classes; Non-inductive loads; Bus duct; Easy-to-read imprint label for quick recognition and replacement; Feeder circuits; UL listed to standard 248-12 File E2137; High degree of current limitation for low peak let-thru current
250V 500A RK1 FUSE
Self-certified for DC per UL248; High degree of current limitation for low peak let-thru current; Fiberglass body provides dimensional stability in harsh industrial environments; Bus duct; Rejection style design prevents replacement by other fuse classes; UL listed to standard 248-12 File E2137; Lighting circuits; Easy-to-read imprint label for quick recognition and replacement; Switchboards; Load centers; Panelboards; Non-inductive loads; Feeder circuits; CSA certified to standard C22.2 No. 248.12
250V 600A RK1 FUSE
Panelboards; CSA certified to standard C22.2 No. 248.12; Rejection style design prevents replacement by other fuse classes; Feeder circuits; UL listed to standard 248-12 File E2137; Bus duct; High degree of current limitation for low peak let-thru current; Self-certified for DC per UL248; Non-inductive loads; Fiberglass body provides dimensional stability in harsh industrial environments; Easy-to-read imprint label for quick recognition and replacement; Lighting circuits; Switchboards; Load centers
250V 450A 10 3/8x2 9/16 T
Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Feeders; Transformers; UL listed to standard 248-12 File E2137; Fiberglass body provides dimensional stability in harsh industrial settings; DC listed to UL standard 248 TRS only; CSA certified to standard C22.2 no. 248.12; Motor circuits; AC & DC rated; Easy-to-read label for quick brand recognition and replacement; Metal-embossed date and catalog number for traceability and lasting identification; High-grade silica filler ensures fast arc quenching and high current limitation; Mains; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Optional solid state SmartSpot blown fuse indicator; Current-limiting; Current-limiting for low peak let-thru current; Branch circuits; Time-delay; General-purpose equipment; Service entrance equipment
250V 450A TD RK5 FUSE SMARTSPO
Current-limiting; Mains; Feeders; Metal-embossed date and catalog number for traceability and lasting identification; AC & DC rated; Current-limiting for low peak let-thru current; Easy-to-read label for quick brand recognition and replacement; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; DC listed to UL standard 248 TRS only; CSA certified to standard C22.2 no. 248.12; Service entrance equipment; Time-delay; Motor circuits; High-grade silica filler ensures fast arc quenching and high current limitation; Transformers; Optional solid state SmartSpot blown fuse indicator; UL listed to standard 248-12 File E2137; Branch circuits; General-purpose equipment; Fiberglass body provides dimensional stability in harsh industrial settings; Rejection-style design prevents replacement errors (when used with recommended fuse blocks)
250V 500A 10 3/8x2 9/16 T
Time-delay; Optional solid state SmartSpot blown fuse indicator; AC & DC rated; Metal-embossed date and catalog number for traceability and lasting identification; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); DC listed to UL standard 248 TRS only; Transformers; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Current-limiting for low peak let-thru current; UL listed to standard 248-12 File E2137; Motor circuits; High-grade silica filler ensures fast arc quenching and high current limitation; Feeders; Easy-to-read label for quick brand recognition and replacement; General-purpose equipment; Branch circuits; Fiberglass body provides dimensional stability in harsh industrial settings; Current-limiting; CSA certified to standard C22.2 no. 248.12; Mains; Service entrance equipment
250V 500A TD RK5 FUSE SMARTSPO
Current-limiting; Current-limiting for low peak let-thru current; Time-delay; Branch circuits; AC & DC rated; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Mains; Service entrance equipment; Optional solid state SmartSpot blown fuse indicator; Fiberglass body provides dimensional stability in harsh industrial settings; CSA certified to standard C22.2 no. 248.12; Transformers; Easy-to-read label for quick brand recognition and replacement; DC listed to UL standard 248 TRS only; Feeders; High-grade silica filler ensures fast arc quenching and high current limitation; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); UL listed to standard 248-12 File E2137; Motor circuits; General-purpose equipment; Metal-embossed date and catalog number for traceability and lasting identification