Search in Category
Filter Your Search
Shop by Category
Fuses
600V 30A 5x13/16 TD FUSE
Rejection-style design prevents replacement errors (when used with recommended fuse blocks); UL listed to standard 248-12 File E2137; Current-limiting for low peak let-thru current; Easy-to-read label for quick brand recognition and replacement; Mains; Motor circuits; Current-limiting; Optional solid state SmartSpot blown fuse indicator; AC & DC rated; Metal-embossed date and catalog number for traceability and lasting identification; Fiberglass body provides dimensional stability in harsh industrial settings; High-grade silica filler ensures fast arc quenching and high current limitation; Branch circuits; General-purpose equipment; Transformers; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Feeders; Service entrance equipment; CSA certified to standard C22.2 no. 248.12; Time-delay; DC listed to UL standard 248 TRS only
600V 5-6/10A RK1 TD FUSE USE
Disconnects; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Fiberglass body provides dimensional stability in harsh industrial settings; Control panels; Recommended for Arc Flash energy reduction; 600VAC & 600VDC dual rated; Reduced inventory by taking the place of class RK5, K, and H fuses; CSA certified to standard C22.2 No. 248.12; DC listed to UL standard 248; Transformers; Safety switches; Branch circuit protection; Solid state SmartSpot visual blown fuse indicator; Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; UL listed to standard 248-12 File E2137; Motors; High-visibility orange label gives instant brand recognition; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; All general-purpose circuits; 300kA interrupting rating – self-certified, UL witnessed tests
600V 6A RK1 TD FUSE
Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; 300kA interrupting rating – self-certified, UL witnessed tests; Safety switches; 600VAC & 600VDC dual rated; DC listed to UL standard 248; Transformers; Reduced inventory by taking the place of class RK5, K, and H fuses; Solid state SmartSpot visual blown fuse indicator; Branch circuit protection; UL listed to standard 248-12 File E2137; Fiberglass body provides dimensional stability in harsh industrial settings; High-visibility orange label gives instant brand recognition; Disconnects; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); CSA certified to standard C22.2 No. 248.12; Motors; All general-purpose circuits; Control panels; Recommended for Arc Flash energy reduction
600V 17-1/2A RK1 TD FUSE
Solid state SmartSpot visual blown fuse indicator; DC listed to UL standard 248; 300kA interrupting rating – self-certified, UL witnessed tests; 600VAC & 600VDC dual rated; Reduced inventory by taking the place of class RK5, K, and H fuses; Motors; Safety switches; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; UL listed to standard 248-12 File E2137; Recommended for Arc Flash energy reduction; High-visibility orange label gives instant brand recognition; Disconnects; All general-purpose circuits; Transformers; Branch circuit protection; CSA certified to standard C22.2 No. 248.12; Time-delay for motor starting and transformer inrush currents without nuisance opening; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Fiberglass body provides dimensional stability in harsh industrial settings; Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; Control panels
H TD FUSE 600V 15A CRS
Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses; CSA Certified
H TD FUSE 600V 17-1/2A CRS
CSA Certified; Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses
H TD FUSE 600V 20A CRS
CSA Certified; Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses
H TD FUSE 600V 25A CRS
CSA Certified; Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses
H TD FUSE 600V 30A CRS
Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses; CSA Certified
600V 1-1/4A RK1 TD FUSE SE
Fiberglass body provides dimensional stability in harsh industrial settings; All general-purpose circuits; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Metal-embossed date and catalog number for easier traceability and lasting identification; Control panels; High-visibility orange label gives instant brand recognition; DC listed to UL standard 248; 600VAC & 600VDC dual rated; Recommended for Arc Flash energy reduction; Time-delay for motor starting and transformer inrush currents without nuisance opening; Transformers; Disconnects; Extremely current-limiting for low peak let-thru current; Solid state SmartSpot visual blown fuse indicator; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Safety switches; CSA certified to standard C22.2 No. 248.12; Branch circuit protection; Motors; Reduced inventory by taking the place of class RK5, K, and H fuses; 300kA interrupting rating – self-certified, UL witnessed tests; UL listed to standard 248-12 File E2137