Search in Category
Filter Your Search
Shop by Category
Fuses
500V CP 10X38 AM 2A C/I FS
Reduced size; Visual indication of fuse operation; Approved by various shipping organizations; IEC 60269-1 & -2 (electrically only for the range with striker); Optional indicator; Safest and most reliable protection system
500V CP 10X38 AM 6A S/I FS
Visual indication of fuse operation; Optional indicator; Approved by various shipping organizations; Safest and most reliable protection system; IEC 60269-1 & -2 (electrically only for the range with striker); Reduced size
A060 URD 0.125 T13
With trip-indicator (1 to 30A), a Mersen speciality; IEC standard 60269-4; (higher ratings without blown fuse indicator 10×38gRB – 690VAC); Voltage rating 500-600 VAC; Without blown fuse indication 0.10 up to 0.80 A; IEC standard 60269-1; aR-Class according to VDE 636-23 IEC 60269-4; VDE 636-23
400V CP 10X38 AM 32A S/I FS
Reduced size; Safest and most reliable protection system; Visual indication of fuse operation; Optional indicator; Approved by various shipping organizations; IEC 60269-1 & -2 (electrically only for the range with striker)
A060 URD 0.160 T13
IEC standard 60269-4; VDE 636-23; With trip-indicator (1 to 30A), a Mersen speciality; Without blown fuse indication 0.10 up to 0.80 A; (higher ratings without blown fuse indicator 10×38gRB – 690VAC); Voltage rating 500-600 VAC; IEC standard 60269-1; aR-Class according to VDE 636-23 IEC 60269-4
500V CP 10X38 GG 6A S/I FS
Visual indication of fuse operation; IEC 60269-1 & -2 (electrically only for the range with striker); Reduced size; Approved by Lloyd’s Register of Shipping and Bureau Veritas; Safest and most reliable protection system; Full range protection
A060 URD 0.200 T13
IEC standard 60269-4; (higher ratings without blown fuse indicator 10×38gRB – 690VAC); aR-Class according to VDE 636-23 IEC 60269-4; With trip-indicator (1 to 30A), a Mersen speciality; Voltage rating 500-600 VAC; Without blown fuse indication 0.10 up to 0.80 A; VDE 636-23; IEC standard 60269-1
6,900 CP GR 10.38 0001
Eliminate all overloads; Current limiting; Excellent cycling capability; Extremely fast acting; UL/CSA Recognized Component; Low I²t for improved semiconductor protection; AC: UL Guide No. E76491; gR Class according to IEC 60269-4 and VDE 636-23; IEC 60269-4 Compliance
500V CP 10x38AM 0.25A S/I FS
Safest and most reliable protection system; Reduced size; Visual indication of fuse operation; Optional indicator; IEC 60269-1 & -2 (electrically only for the range with striker); Approved by various shipping organizations
6,900 CP GR 10.38 0012.5
Excellent cycling capability; AC: UL Guide No. E76491; UL/CSA Recognized Component; Low I²t for improved semiconductor protection; gR Class according to IEC 60269-4 and VDE 636-23; IEC 60269-4 Compliance; Extremely fast acting; Eliminate all overloads; Current limiting