Browse Categories

Search in Category

Fuses

Search Filters

  • Mersen x
  • 1.06 in x

Shop by Category

Loading...

Fuses

Power Products/Fuses 
Viewing Page 10 of 18 (180 results)

821 CP GRB 2760 32

Item #: Y221442

Supplier Part #: Y221442
Brand: Mersen

The 800VAC Protistor® BS88-4 fuse-link provides maximum flexibility in equipment design and ultimate protection for small power conversion equipment. These fast acting gR fuses have been engineered to provide full range protection to eliminate all overloads and semiconductor fault. They are assembled with die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. Each fuse-link is embedded with a trip-indicator.

Extremely fast acting; International size 27×60 mm for worldwide acceptance; Low I²t for improved semiconductor protection; Selective coordination with other fuses; Excellent cycling capability; IEC 60269-4 Compliance; Eliminate all overloads

Call
NOT CURRENTLY IN STOCK

821 CP GRB 2760 16

Item #: V221439

Supplier Part #: V221439
Brand: Mersen

The 800VAC Protistor® BS88-4 fuse-link provides maximum flexibility in equipment design and ultimate protection for small power conversion equipment. These fast acting gR fuses have been engineered to provide full range protection to eliminate all overloads and semiconductor fault. They are assembled with die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. Each fuse-link is embedded with a trip-indicator.

Eliminate all overloads; Low I²t for improved semiconductor protection; IEC 60269-4 Compliance; International size 27×60 mm for worldwide acceptance; Excellent cycling capability; Selective coordination with other fuses; Extremely fast acting

Call
NOT CURRENTLY IN STOCK

J TD FUSE 600V 35A AJT

Item #: AJT35

Supplier Part #: AJT35
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Control panels; Bus duct; DC listed to UL standard 248; Unique Class J dimensions prevent replacement errors; Load centers; High-visibility orange label gives instant brand recognition; Mains; Transformers; Recommended for Arc Flash energy reduction; Most current-limiting UL class fuse; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; IEC 60269-2-1; Circuit breaker back-up; Metal-embossed date and catalog number for traceability and lasting identification; UL listed to standard 248-8 File E2137; High-grade silica filler ensures fast arc quenching; DC tested to UL standard 248; Lighting, heating & general loads; Branch circuits; Motor circuits; Feeders; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Time-delay for motor starting and transformer inrush; Extremely current-limiting for low peak let-thru current; CSA certified to standard C22.2 No. 248.8; Non-indicating or solid state SmartSpot visual blown fuse indicator; 300kA interrupting rating – self-certified, UL witnessed tests; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Fiberglass body provides dimensional stability in harsh industrial settings; UL listed

Call
NOT CURRENTLY IN STOCK
600V 50A  J TD NON-IND

600V 50A J TD NON-IND

Item #: AJT50N

Supplier Part #: AJT50N
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Time-delay for motor starting and transformer inrush; Unique Class J dimensions prevent replacement errors; Circuit breaker back-up; DC tested to UL standard 248; Lighting, heating & general loads; Bus duct; Most current-limiting UL class fuse; Control panels; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; UL listed to standard 248-8 File E2137; IEC 60269-2-1; Feeders; UL listed; Fiberglass body provides dimensional stability in harsh industrial settings; Non-indicating or solid state SmartSpot visual blown fuse indicator; Branch circuits; Extremely current-limiting for low peak let-thru current; 300kA interrupting rating – self-certified, UL witnessed tests; Load centers; High-visibility orange label gives instant brand recognition; Transformers; Mains; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; High-grade silica filler ensures fast arc quenching; DC listed to UL standard 248; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Recommended for Arc Flash energy reduction; Motor circuits; Metal-embossed date and catalog number for traceability and lasting identification; CSA certified to standard C22.2 No. 248.8

Call
NOT CURRENTLY IN STOCK

600V 70A CLASS J TD FUSE

Item #: AJT70

Supplier Part #: AJT70
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Time-delay for motor starting and transformer inrush; Branch circuits; DC tested to UL standard 248; Mains; High-grade silica filler ensures fast arc quenching; 300kA interrupting rating – self-certified, UL witnessed tests; Circuit breaker back-up; DC listed to UL standard 248; Most current-limiting UL class fuse; UL listed to standard 248-8 File E2137; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Motor circuits; Transformers; Lighting, heating & general loads; Metal-embossed date and catalog number for traceability and lasting identification; IEC 60269-2-1; Recommended for Arc Flash energy reduction; CSA certified to standard C22.2 No. 248.8; Feeders; Non-indicating or solid state SmartSpot visual blown fuse indicator; Control panels; Extremely current-limiting for low peak let-thru current; Fiberglass body provides dimensional stability in harsh industrial settings; Unique Class J dimensions prevent replacement errors; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Load centers; UL listed; High-visibility orange label gives instant brand recognition; Bus duct; Easy 2-to-1 selectivity for prevention of nuisance shutdowns

Call
NOT CURRENTLY IN STOCK
J TD FUSE 600V 70A AJT

J TD FUSE 600V 70A AJT

Item #: AJT70EI

Supplier Part #: AJT70EI
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; UL listed; Branch circuits; Non-indicating or solid state SmartSpot visual blown fuse indicator; Control panels; Metal-embossed date and catalog number for traceability and lasting identification; Most current-limiting UL class fuse; CSA certified to standard C22.2 No. 248.8; IEC 60269-2-1; High-grade silica filler ensures fast arc quenching; Mains; UL listed to standard 248-8 File E2137; Feeders; 300kA interrupting rating – self-certified, UL witnessed tests; Extremely current-limiting for low peak let-thru current; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Transformers; Time-delay for motor starting and transformer inrush; Lighting, heating & general loads; High-visibility orange label gives instant brand recognition; Motor circuits; Recommended for Arc Flash energy reduction; Unique Class J dimensions prevent replacement errors; Bus duct; DC tested to UL standard 248; Load centers; Fiberglass body provides dimensional stability in harsh industrial settings; DC listed to UL standard 248; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Circuit breaker back-up

Call
NOT CURRENTLY IN STOCK
J TD FUSE 600V 80A AJT

J TD FUSE 600V 80A AJT

Item #: AJT80EI

Supplier Part #: AJT80EI
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Extremely current-limiting for low peak let-thru current; IEC 60269-2-1; Circuit breaker back-up; UL listed to standard 248-8 File E2137; Motor circuits; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Fiberglass body provides dimensional stability in harsh industrial settings; Non-indicating or solid state SmartSpot visual blown fuse indicator; Time-delay for motor starting and transformer inrush; Feeders; Branch circuits; Transformers; DC tested to UL standard 248; Mains; Lighting, heating & general loads; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; CSA certified to standard C22.2 No. 248.8; Most current-limiting UL class fuse; Load centers; Metal-embossed date and catalog number for traceability and lasting identification; DC listed to UL standard 248; UL listed; High-visibility orange label gives instant brand recognition; 300kA interrupting rating – self-certified, UL witnessed tests; Unique Class J dimensions prevent replacement errors; Control panels; Recommended for Arc Flash energy reduction; High-grade silica filler ensures fast arc quenching; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Bus duct

Call
NOT CURRENTLY IN STOCK

6921 CP URGD 2760 100

Item #: C076822

Supplier Part #: C076822
Brand: Mersen

Extremely high breaking capacity fuses Protection of power semiconductors Complying with standard IEC 60269-1 and -4 600-690VAC voltage rating aR class according to IEC 60269-4 and VDE 636-23

Extremely breaking capacity rating fuses; VDE 636-23; IEC 60269.1; IEC 60269.4

Call
NOT CURRENTLY IN STOCK

CC6621 CP GRB 2760 20

Item #: C077006

Supplier Part #: C077006
Brand: Mersen

Mersen DC offers provide a very high performant protection for railway power and auxiliary circuits. Mersen DC Semiconductor fuse-links were developed to provide improved performance required by today's new DC equipment. These fuse-links are typically operated at more elevated temperature than other fuse type, have lower I²t to minimize damage to protected components on short circuits, lower watts loss and longer life.
Call
NOT CURRENTLY IN STOCK

821 CP GRB 2760 80

Item #: C221446

Supplier Part #: C221446
Brand: Mersen

The 800VAC Protistor® BS88-4 fuse-link provides maximum flexibility in equipment design and ultimate protection for small power conversion equipment. These fast acting gR fuses have been engineered to provide full range protection to eliminate all overloads and semiconductor fault. They are assembled with die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. Each fuse-link is embedded with a trip-indicator.

Low I²t for improved semiconductor protection; Selective coordination with other fuses; Extremely fast acting; Excellent cycling capability; IEC 60269-4 Compliance; International size 27×60 mm for worldwide acceptance; Eliminate all overloads

Call
NOT CURRENTLY IN STOCK
  • « PREV
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • NEXT »