ERIFLEX FLEXIBAR 3MTC 3X80X1

ERIFLEX FLEXIBAR 3MTC 3X80X1

Item #: 505539

Supplier Part #: 505539
Brand: nVent Eriflex

nVent ERIFLEX Flexibar, Tinned Copper, 800 A, UL 67, UL 758 Certification Details, 3.15" x 0.039", 473.65 kcmil

Dramatically smaller and more flexible than comparable cable based on ampacity; Reduces total installation cost; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the nVent ERIFLEX Flexibar, or welding using nVent ERICO Cadweld; RoHS; Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint; No lugs needed, reducing installation time and improving resistance to vibration; Bureau Veritas – ACE 14/163/02; Traceability codes and designation part numbers printed on insulation; Thin layers of tinned electrolytic copper formed into a stack; UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F); UR – ANSI/UL 758; Better power density than cable with lower skin effect ratio; ABS; Insulated by high-resistance, self-extinguishing PVC with less than 20% contact with conductor for high flexibility; Tinned copper allows for copper or aluminum conductor connections; CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; 100% production dielectric tested; CE, ERIFLEX FLEXIBAR – EN 61439-1; UR – ANSI/UL 67, ANSI/UL 891; RoHS compliant; EAC compliant; Weight savings and material savings compared to wire alternatives

Call
NOT CURRENTLY IN STOCK
ERIFLEX FLEXIBAR 3MTC 8X80X1

ERIFLEX FLEXIBAR 3MTC 8X80X1

Item #: 505543

Supplier Part #: FLEX3MTC8X80X1
Brand: nVent Eriflex

nVent ERIFLEX Flexibar, Tinned Copper, 1,600 A, UL 67, UL 758 Certification Details, 3.15" x 0.039", 1,263.06 kcmil

Better power density than cable with lower skin effect ratio; No lugs needed, reducing installation time and improving resistance to vibration; UR – ANSI/UL 67, ANSI/UL 891; Insulated by high-resistance, self-extinguishing PVC with less than 20% contact with conductor for high flexibility; Tinned copper allows for copper or aluminum conductor connections; Bureau Veritas – ACE 14/163/02; RoHS; CE, ERIFLEX FLEXIBAR – EN 61439-1; UR – ANSI/UL 758; Thin layers of tinned electrolytic copper formed into a stack; Dramatically smaller and more flexible than comparable cable based on ampacity; 100% production dielectric tested; RoHS compliant; Traceability codes and designation part numbers printed on insulation; ABS; Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint; Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the nVent ERIFLEX Flexibar, or welding using nVent ERICO Cadweld; CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F); cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; Weight savings and material savings compared to wire alternatives; EAC compliant; Reduces total installation cost

Call
NOT CURRENTLY IN STOCK
ERIFLEX FLEXIBAR 3MTC 5X100X1

ERIFLEX FLEXIBAR 3MTC 5X100X1

Item #: 505546

Supplier Part #: FLEX3MTC5X100X1
Brand: nVent Eriflex

nVent ERIFLEX Flexibar, Tinned Copper, 1,600 A, UL 67, UL 758 Certification Details, 3.937" x 0.039", 986.76 kcmil

UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F); Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint; Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the nVent ERIFLEX Flexibar, or welding using nVent ERICO Cadweld; UR – ANSI/UL 67, ANSI/UL 891; Bureau Veritas – ACE 14/163/02; Dramatically smaller and more flexible than comparable cable based on ampacity; RoHS compliant; Thin layers of tinned electrolytic copper formed into a stack; RoHS; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; No lugs needed, reducing installation time and improving resistance to vibration; ABS; Better power density than cable with lower skin effect ratio; EAC compliant; CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; Insulated by high-resistance, self-extinguishing PVC with less than 20% contact with conductor for high flexibility; UR – ANSI/UL 758; Weight savings and material savings compared to wire alternatives; Reduces total installation cost; 100% production dielectric tested; Tinned copper allows for copper or aluminum conductor connections; Traceability codes and designation part numbers printed on insulation; CE, ERIFLEX FLEXIBAR – EN 61439-1

Call
NOT CURRENTLY IN STOCK
Insulated Braided conductor IBSB ADVANCE

Insulated Braided conductor IBSB ADVANCE

Item #: 534441

Supplier Part #: IBSBADV240-330
Brand: nVent Eriflex

IBS/IBSB Advanced Flat Insulated Braided Power Conductor, Halogen Free. IBSBADV240-330, 630 A, 240 mm², 32 mm x 9.2 mm x 330 mm (1.26" x 0.36" x 12.99").

Bureau Veritas – ACE 14/163/3; UL – UL94-V0; CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; UL (IEC) – UL 2885 – IEC 60754-1, IEC 60754-2, IEC 62821-1 Annex B, IEC 61034-2; ABS; Improves assembly flexibility and aesthetics; Resistant to vibration, improving reliability and performance; No additional cutting, stripping, crimping and punching needed; Quick and easy installation; UR – ANSI/UL 67, ANSI/UL 891; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; Dramatically smaller and more flexible than comparable cable based on ampacity; Tinned copper provides superior corrosion resistance; DNV GL® and Bureau Veritas certified for marine and offshore applications; ISO 5659-2 – ISO 5659-2; IEC 60695-2-12 – IEC 60695-2-12; Tinned copper allows for copper or aluminum conductor connections; ERIFLEX UV – IEC 60364-5-52, ISO 4892-2; Conforms to NF EN 45545 obtaining an HL3 classification for chapters R22 and R23; UR – ANSI/UL 758; CE, ERIFLEX IBSADV? – EN IEC 61439-1?; On request, can be manufactured with other colors (typically with Orange sleeve for battery connection); Small wire diameter provides maximum flexibility; Suitable for all main molded case circuit breakers; Insulated by high-resistance, halogen free, flame retardant and low smoke material; DNV GL – DNV GL Rules; Integral palm without lugs or terminals reduces material and assembly weight; RoHS; EN 45545-2 – EN 45545-2; CE; Better power density than cable with lower skin effect ratio; RoHS compliant; IEC 61439-1 Class II – IEC 61439-1 Class II; IEC 61439-1 – IEC 61439-1; Reduces total installation cost; CSA – C22.2 No 210; EAC

$77.19 /EA
NOT CURRENTLY IN STOCK
Insulated Braided conductor IBSB ADVANCE

Insulated Braided conductor IBSB ADVANCE

Item #: 534443

Supplier Part #: IBSBADV240-530
Brand: nVent Eriflex

IBS/IBSB Advanced Flat Insulated Braided Power Conductor, Halogen Free. IBSBADV240-530, 630 A, 240 mm², 32 mm x 9.2 mm x 530 mm (1.26" x 0.36" x 20.87").

IEC 61439-1 Class II – IEC 61439-1 Class II; On request, can be manufactured with other colors (typically with Orange sleeve for battery connection); Dramatically smaller and more flexible than comparable cable based on ampacity; IEC 61439-1 – IEC 61439-1; EN 45545-2 – EN 45545-2; Resistant to vibration, improving reliability and performance; DNV GL – DNV GL Rules; Bureau Veritas – ACE 14/163/3; Quick and easy installation; ERIFLEX UV – IEC 60364-5-52, ISO 4892-2; Conforms to NF EN 45545 obtaining an HL3 classification for chapters R22 and R23; No additional cutting, stripping, crimping and punching needed; UL (IEC) – UL 2885 – IEC 60754-1, IEC 60754-2, IEC 62821-1 Annex B, IEC 61034-2; IEC 60695-2-12 – IEC 60695-2-12; UR – ANSI/UL 67, ANSI/UL 891; RoHS; ABS; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; Tinned copper allows for copper or aluminum conductor connections; CSA – C22.2 No 210; CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; EAC; DNV GL® and Bureau Veritas certified for marine and offshore applications; Insulated by high-resistance, halogen free, flame retardant and low smoke material; Small wire diameter provides maximum flexibility; ISO 5659-2 – ISO 5659-2; Reduces total installation cost; UL – UL94-V0; CE; Suitable for all main molded case circuit breakers; Tinned copper provides superior corrosion resistance; Better power density than cable with lower skin effect ratio; CE, ERIFLEX IBSADV? – EN IEC 61439-1?; Improves assembly flexibility and aesthetics; Integral palm without lugs or terminals reduces material and assembly weight; UR – ANSI/UL 758; RoHS compliant

$109.40 /EA
NOT CURRENTLY IN STOCK
Insulator ISO TP 45M8L

Insulator ISO TP 45M8L

Item #: 548550

Supplier Part #: ISOTP45M8L
Brand: nVent Eriflex

Low voltage electrical insulator. ISOTP45M8L, Metric Thread, 1.772" (45 mm), 50 mm Hex Width, M8 Thread.

UL® Recognized in E125470 and evaluated for dielectric withstand rating of 1,500 VAC/DC; CSA-Comp – CSA C22.2 No. 29; UR – ANSI/UL 67, ANSI/UL 891; High resistance to leakage current; Great stability of electrical and mechanical parameters; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; IEC 61439-1 – IEC 61439-1 (2017); Halogen free; RoHS; RoHS compliant; CE, ERIFLEX ISOTP – EN 61439; Fiberglass reinforced

$4.62 /EA
NOT CURRENTLY IN STOCK
Insulator ISO TP 50M8

Insulator ISO TP 50M8

Item #: 548580

Supplier Part #: ISOTP50M8
Brand: nVent Eriflex

Low voltage electrical insulator. ISOTP50M8, Metric Thread, 1.969" (50 mm), 50 mm Hex Width, M8 Thread.

Great stability of electrical and mechanical parameters; CE, ERIFLEX ISOTP – EN 61439; Halogen free; UL® Recognized in E125470 and evaluated for dielectric withstand rating of 1,500 VAC/DC; UR – ANSI/UL 67, ANSI/UL 891; CSA-Comp – CSA C22.2 No. 29; RoHS compliant; RoHS; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; IEC 61439-1 – IEC 61439-1 (2017); High resistance to leakage current; Fiberglass reinforced

$6.16 /EA
NOT CURRENTLY IN STOCK
ERIFLEX FLEXIBAR 3MTC 2X24X1

ERIFLEX FLEXIBAR 3MTC 2X24X1

Item #: 505506

Supplier Part #: FLEX3MTC2X24X1
Brand: nVent Eriflex

nVent ERIFLEX Flexibar, Tinned Copper, 250 A, UL 67, UL 758 Certification Details, 0.945" x 0.039", 94.73 kcmil

CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; No lugs needed, reducing installation time and improving resistance to vibration; Tinned copper allows for copper or aluminum conductor connections; Better power density than cable with lower skin effect ratio; Bureau Veritas – ACE 14/163/02; Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the nVent ERIFLEX Flexibar, or welding using nVent ERICO Cadweld; Thin layers of tinned electrolytic copper formed into a stack; Weight savings and material savings compared to wire alternatives; Dramatically smaller and more flexible than comparable cable based on ampacity; 100% production dielectric tested; RoHS compliant; Insulated by high-resistance, self-extinguishing PVC with less than 20% contact with conductor for high flexibility; UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F); ABS; RoHS; UR – ANSI/UL 758; UR – ANSI/UL 67, ANSI/UL 891; Traceability codes and designation part numbers printed on insulation; CE, ERIFLEX FLEXIBAR – EN 61439-1; Reduces total installation cost; EAC compliant

Call
NOT CURRENTLY IN STOCK
ERIFLEX FLEXIBAR 3MTC 4X32X1

ERIFLEX FLEXIBAR 3MTC 4X32X1

Item #: 505515

Supplier Part #: FLEX3MTC4X32X1
Brand: nVent Eriflex

nVent ERIFLEX Flexibar, Tinned Copper, 400 A, UL 67, UL 758 Certification Details, 1.26" x 0.039", 252.6 kcmil

CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; UR – ANSI/UL 758; Reduces total installation cost; Bureau Veritas – ACE 14/163/02; RoHS compliant; Weight savings and material savings compared to wire alternatives; Thin layers of tinned electrolytic copper formed into a stack; Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint; Traceability codes and designation part numbers printed on insulation; CE, ERIFLEX FLEXIBAR – EN 61439-1; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; ABS; RoHS; Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the nVent ERIFLEX Flexibar, or welding using nVent ERICO Cadweld; EAC compliant; 100% production dielectric tested; Dramatically smaller and more flexible than comparable cable based on ampacity; UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F); Tinned copper allows for copper or aluminum conductor connections; Insulated by high-resistance, self-extinguishing PVC with less than 20% contact with conductor for high flexibility; UR – ANSI/UL 67, ANSI/UL 891; Better power density than cable with lower skin effect ratio; No lugs needed, reducing installation time and improving resistance to vibration

Call
NOT CURRENTLY IN STOCK
ERIFLEX FLEXIBAR 3MTC 10X50X1

ERIFLEX FLEXIBAR 3MTC 10X50X1

Item #: 505532

Supplier Part #: FLEX3MTC10X50X1
Brand: nVent Eriflex

nVent ERIFLEX Flexibar, Tinned Copper, 1,200 A, UL 67, UL 758 Certification Details, 1.969" x 0.039", 986.76 kcmil

Reduces total installation cost; CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F); Weight savings and material savings compared to wire alternatives; RoHS; Traceability codes and designation part numbers printed on insulation; UR – ANSI/UL 67, ANSI/UL 891; CE, ERIFLEX FLEXIBAR – EN 61439-1; EAC compliant; ABS; Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the nVent ERIFLEX Flexibar, or welding using nVent ERICO Cadweld; Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; Thin layers of tinned electrolytic copper formed into a stack; Insulated by high-resistance, self-extinguishing PVC with less than 20% contact with conductor for high flexibility; Dramatically smaller and more flexible than comparable cable based on ampacity; Better power density than cable with lower skin effect ratio; 100% production dielectric tested; No lugs needed, reducing installation time and improving resistance to vibration; Tinned copper allows for copper or aluminum conductor connections; RoHS compliant; UR – ANSI/UL 758; Bureau Veritas – ACE 14/163/02

Call
NOT CURRENTLY IN STOCK