Search in Category
AC Drives
Search term required.
Search Filters
-
3.543 in x
Filter Your Search
Brand
Height
Number of digital outputs
Shop by Category
Loading...
AC Motor Drives
Viewing Page 4 of 6
(53 results)
DR AC G110 230V 1PU 1HP 4.2A AN NOR
Item #:
6SL32110AB175UA1
Supplier Part #: 6SL3211-0AB17-5UA1
Brand:
Siemens
SINAMICS g110 - cpm110 AC-drive, without filter 1AC200-240v +10/-10% 47-63HZ analog input ct 0.75KW vt 0.75KW ct-overload 150% 60s 150 x 90 x 131 (hxwxd) protection IP20 ambient temp -10 to +40 deg c without bop without rs485-interface
Call
NOT CURRENTLY IN STOCK
DR AC G110 230V 1PU 1HP 4.2A USS NOR
Item #:
6SL32110AB175UB1
Supplier Part #: 6SL3211-0AB17-5UB1
Brand:
Siemens
SINAMICS g110 - cpm110 AC-drive, without filter 1AC200-240v +10/-10% 47-63HZ rs485-interface (uss-protocol) ct 0.75KW vt 0.75KW ct-overload 150% 60s 150 x 90 x 131 (hxwxd) protection IP20 ambient temp -10 to +40 deg c without bop without analog input
Call
NOT CURRENTLY IN STOCK
G110 CPM110 1AC230 0,12KW FB AIN IP20 CP
Item #:
6SL32110KB112BA1
Supplier Part #: 6SL3211-0KB11-2BA1
Brand:
Siemens
SINAMICS g110 - cpm110 AC-drive,built in cl. b filter 1AC200-240v +10/-10% 47-63HZ analog input ct 0.12KW vt 0.12KW ct-overload 150% 60s 150 x 90 x 101 (hxwxd) IP20 with flat heatsink coldplate assembly only ambient temp -10 to +50 deg c without bop without rs485-interface
Call
NOT CURRENTLY IN STOCK
DR AC G110 240V, 0.12HP FLT HEAT SINK
Item #:
6SL32110KB112BB1
Supplier Part #: 6SL3211-0KB11-2BB1
Brand:
Siemens
SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT 0.12KW VT 0.12KW CT-OVERLOAD 150% 60S 150 X 90 X 101 (HXWXD) IP20 WITH FLAT HEATSINK COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG INPUT
Call
NOT CURRENTLY IN STOCK
G110 CPM110 1AC230 0,12KW UF AIN IP20 CP
Item #:
6SL32110KB112UA1
Supplier Part #: 6SL3211-0KB11-2UA1
Brand:
Siemens
SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT 0.12KW VT 0.12KW CT-OVERLOAD 150% 60S 150 X 90 X 101 (HXWXD) IP20 WITH FLAT HEATSINK COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE
Call
NOT CURRENTLY IN STOCK
G110 CPM110 1AC230 0,12KW UF USS IP20 CP
Item #:
6SL32110KB112UB1
Supplier Part #: 6SL3211-0KB11-2UB1
Brand:
Siemens
SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT 0.12KW VT 0.12KW CT-OVERLOAD 150% 60S 150 X 90 X 101 (HXWXD) IP20 WITH FLAT HEATSINK COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG INPUT
Call
NOT CURRENTLY IN STOCK
G110 CPM110 1AC230 0,25KW FB AIN IP20 CP
Item #:
6SL32110KB125BA1
Supplier Part #: 6SL3211-0KB12-5BA1
Brand:
Siemens
SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT 0.25KW VT 0.25KW CT-OVERLOAD 150% 60S 150 X 90 X 101 (HXWXD) IP20 WITH FLAT HEATSINK COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE
Call
NOT CURRENTLY IN STOCK
DR AC G110 240V, 0.25HP FLT HEAT SINK
Item #:
6SL32110KB125BB1
Supplier Part #: 6SL3211-0KB12-5BB1
Brand:
Siemens
SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT 0.25KW VT 0.25KW CT-OVERLOAD 150% 60S 150 X 90 X 101 (HXWXD) IP20 WITH FLAT HEATSINK COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG INPUT
Call
NOT CURRENTLY IN STOCK
G110 CPM110 1AC230 0,25KW UF AIN IP20 CP
Item #:
6SL32110KB125UA1
Supplier Part #: 6SL3211-0KB12-5UA1
Brand:
Siemens
SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT 0.25KW VT 0.25KW CT-OVERLOAD 150% 60S 150 X 90 X 101 (HXWXD) IP20 WITH FLAT HEATSINK COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE
Call
NOT CURRENTLY IN STOCK
G110 CPM110 1AC230 0,25KW UF USS IP20 CP
Item #:
6SL32110KB125UB1
Supplier Part #: 6SL3211-0KB12-5UB1
Brand:
Siemens
SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT 0.25KW VT 0.25KW CT-OVERLOAD 150% 60S 150 X 90 X 101 (HXWXD) IP20 WITH FLAT HEATSINK COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG INPUT
Call
NOT CURRENTLY IN STOCK