Viewing Page 1 of 3 (25 results)
ETHERNET,CONTROLLER,CP 343-1,S7-300

ETHERNET,CONTROLLER,CP 343-1,S7-300


Supplier Part #: 6GK7343-1GX31-0XE0
Brand: Siemens

SIMATIC NET CP 343-1 ADVANCED; FOR CONNECTING SIMATIC S7-300 CPU TO IND. ETHERNET; PROFINET IO CONTROLLER AND/OR IO-DEVICE; RT AND RT AND IRT IRT, MRP, PROFINET CBA; TCP/IP; ISO,UDP,S7-COM,S5-KOMP. COM., (SEND/RECEIVE) W. FETCH/WRITE WITH AND WITHOUT RFC 1006, MULTICAST DIAGNOSIS EXTENSION, SNMP, DHCP, FTP CLIENT/SERVER, E-MAIL, GIGABIT-SS1X RJ45 (10/100/1000) PROFINET-SS 2X RJ45(10/100MBIT) PROFINET CBA; SECURITY (FIREWALL/VPN); PROFIENERGY
$4,850.00 /EA
NOT CURRENTLY IN STOCK

FM350-2, COUNTER MOD., 8 CHANNELS, 20KHZ


Supplier Part #: 6ES7350-2AH01-0AE0
Brand: Siemens

SIMATIC S7-300, COUNTER MODULE FM 350-2, 8 CHANNELS, 20 KHZ, 24V ENCODER FOR COUNTING, MEASURING FREQUENCIES, SPEED MEASUREMENT, PERIOD DURATION MEASUREMENT AND PROPORTIONING INCL. CONFIG. PACKAGE AND ELECTRONIC DOCU ON CD
$2,670.00 /EA
NOT CURRENTLY IN STOCK
REPEATER DIAG DP 12MB FAST-CONNECT IP20

REPEATER DIAG DP 12MB FAST-CONNECT IP20


Supplier Part #: 6ES7972-0AB01-0XA0
Brand: Siemens

SIMATIC s7, diagnosis-repeater for PROFIBUS dp, for online PROFIBUS cable diagnostics, dp-standard slave to 12mbit/s, degree of protection IP20, fast-connect technology
$1,850.00 /EA
NOT CURRENTLY IN STOCK

CPU 313C-2 PtP


Supplier Part #: 6ES7313-6BG04-0AB0
Brand: Siemens

SIMATIC S7-300, CPU 313C-2 PTP Compact CPU with MPI, 16 DI/16 DO, 3 high-speed counters (30 kHz), integrated interface RS485, Integr. power supply 24 V DC, work memory 128 KB, Front connector (1x 40-pole) and Micro Memory Card required
$2,675.00 /EA
NOT CURRENTLY IN STOCK

SIPLUS S7-300 CPU312C EN50155


Supplier Part #: 6AG1312-5BF04-2AY0
Brand: Siemens

SIPLUS S7-300 CPU 312C with conformal coating according to EN 50155 T1 Cat 1 Cl A/ B based on 6ES7312-5BF04-0AB0 . Compact CPU with MPI. 10 DI/6 DQ. 2 high-speed counters (10 kHz) Integr. power supply 24 V DC. work memory 64 KB. Front connector (1x 40-pole) and Micro Memory Card required
$3,568.00 /EA
NOT CURRENTLY IN STOCK

SIPLUS S7-300 CPU313C-2DP


Supplier Part #: 6AG1313-6CG04-7AB0
Brand: Siemens

SIPLUS S7-300 CPU313C-2DP FOR MEDIAL STRESS -25 ... +70 DEGREES C BASED ON 6ES7313-6CG04-0AB0 . COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1 X 40PIN) AND MICRO MEMORY CARD REQUIRED
$5,275.00 /EA
NOT CURRENTLY IN STOCK
SIPLUS NET CP343-1 ADVANCED

SIPLUS NET CP343-1 ADVANCED


Supplier Part #: 6AG1343-1GX31-4XE0
Brand: Siemens

SIPLUS NET CP343-1 ADVANCED WITH CONFORMAL COATING BASED ON 6GK7343-1GX31-0XE0 . FOR CONNECTING SIMATIC S7-300 CPU TO IND. ETHERNET; PROFINET IO CONTROLLER AND/OR IO-DEVICE; RT AND RT AND IRT IRT, MRP, PROFINET CBA; TCP/IP; ISO,UDP,S7-COM,S5-KOMP. COM., (SEND/RECEIVE) W. FETCH/WRITE WITH AND WITHOUT RFC 1006, MULTICAST DIAGNOSIS EXTENSION, SNMP, DHCP, FTP CLIENT/SERVER, E-MAIL, GIGABIT-SS1X RJ45 (10/100/1000) PROFINET-SS 2X RJ45(10/100MBIT) PROFINET CBA; SECURITY (FIREWALL/VPN); PROFIENERGY
$5,910.00 /EA
NOT CURRENTLY IN STOCK

SIPLUS S7-300 FM350-2 8 CHANNELS,COATED


Supplier Part #: 6AG1350-2AH01-4AE0
Brand: Siemens

SIPLUS S7-300 FM350-2 8 CHANNEL FOR MEDIAL STRESS WITH CONFORMAL COATING BASED ON 6ES7350-2AH01-0AE0 . REPLACEMENT FOR 6AG1350-2AH00-4AE0
$4,270.00 /EA
NOT CURRENTLY IN STOCK
SIPLUS DP DIAGNOSE-REPEATER

SIPLUS DP DIAGNOSE-REPEATER


Supplier Part #: 6AG1972-0AB01-4XA0
Brand: Siemens

SIPLUS DP DIAGNOSIS-REPEATER FOR MEDIAL STRESS WITH CONFORMAL COATING BASED ON 6ES7972-0AB01-0XA0
$2,680.00 /EA
NOT CURRENTLY IN STOCK
COUPLER DIST.I/0 FIELD BUS RS485-IS

COUPLER DIST.I/0 FIELD BUS RS485-IS


Supplier Part #: 6ES7972-0AC80-0XA0
Brand: Siemens

SIMATIC DP, DISTRIBUTED I/O FIELD DEVICE LINK RS485-IS COUPLER, FIELD BUS COUPLER BETWEEN PROFIBUS DP AND RS485-IS, TO HEADING FOR INTRINSICALLY SAFE PROFBUS PARTICIPANTS, INSTALLATION IN EX-AREA2, FOR EXPANDED TEMPERATURE RANGE PROTECTION CLASS IP20
$1,565.60 /EA
NOT CURRENTLY IN STOCK
  • 1
  • 2
  • 3
  • NEXT »

What is a PLC?

A programmable logic controller, or PLC, is a computer used for industrial automation that continuously monitors the state of integrated input devices and makes decisions based upon custom programs to control the state of output devices. These controllers can be used to automate processes, machine functions, or even an entire production line. PLCs are modular systems in that you can mix and match input and output devices to best suit your given application. The largest benefit in using a PLC is the ability to change and replicate a process or operation while vital information is collected and communicated.

How Does a PLC Operate?

A PLC receives information from connected sensors or input devices before processing the data and triggering outputs based on pre-programmed parameters. There are four basic steps in the operation of all programmable logic controllers; Input Scan, Program Scan, Output Scan, and Housekeeping. These steps take place in a repeating loop.

4 Steps in PLC Control Systems

  1. Input Scan
    • State of all input devices connected are detected.
  2. Program Scan
    • User created program logic is executed.
  3. Output Scan
    • All output devices connected are energized or de-energized.
  4. Housekeeping
    • Communications with programming terminals, internal diagnostics, etc…

Depending on the specific inputs and outputs, a PLC can monitor and record run-time data such as machine productivity or operating temperature, automatically start and stop processes, generate alarms if a machine malfunctions, and more. Programmable logic controllers are flexible and a robust control solution that is adaptable to almost any application.

What is Inside a PLC?

The Central Processing Unit, the CPU, contains an internal program that tells the PLC how to perform functions similar to the following:

  • Control instructions located in the user’s programs are executed. This program is stored in “nonvolatile” memory, meaning that if power is removed, the program will not be lost.
  • Communicate with other devices including I/O devices, programming devices, networks, and other PLCs.
  • Communications, internal diagnostics, etc.

There are a few key features that set programmable logic controllers away from industrial PCs microcontrollers and other industrial control solutions.

  • Input/Output (I/O): The CPU in the PLC stores and processes program data, but input and output modules connect the it to the rest of the machine. I/O modules are what provide information to the CPU and trigger specific results. These can either be analog or digital devices. Input devices may include sensors, switches, and meters while output devices might include relays, lights, valves, and drives. Devices can be mixed and matched for use with a PLC in order to get the correct configuration for their application.
  • Human Machine Interface (HMI): A human machine interface (HMI) is needed in order to interact with a programmable logic controller in real time. These devices enable users to review and input information to the PLC through a simple display with a text-readout and keypad, or a large touchscreen panel that is more similar to consumer electronics.
  • Communications: In addition to I/O devices, there may be use cases for a PLC to connect with other types of systems. Users might want to export data related to an application that was recorded by connected devices to a supervisory control and data acquisition (SCADA) system which has the ability to monitor multiple connected devices. All PLCs offer a range of ports and communication protocols to ensure that it can communicate with other systems.

What are Input/Output Devices?

Input and output devices are any hardware used by a human operator or other systems to communicate or interface with a computer. I/O devices, as the name implies, are capable of delivering data (output) to and receiving data from (input) a computer. Examples of such devices commonly used with a PLC are below:

InputOutput
  • Switches and pushbuttons
  • Sensing devices
    • Limit Switches
    • Photoelectric Sensors
    • Proximity Sensors
  • Condition Sensors
  • Encoders
    • Pressure Switches
    • Level Switches
    • Temperature Switches
    • Vacuum Switches
    • Float Switches
  • Valves
  • Starters (motors)
  • Solenoids
  • Actuators
  • Horns/Alarms
  • Stack Lights
  • Control Relays
  • Counters
  • Pumps
  • Printers
  • Fans

What to Consider when Choosing a PLC?

Every machine and industrial process that must operate in tandem with other components require precise controls that dictate how they operate. While PLC manufacturers can help you select the controller that will work best in your process, it pays to understand the variables that make specific programmable logic controllers best for particular operations. Below are some of the key factors to keep in mind when selecting a PLC:

  1. Power Supply: Will the system be powered by AC or DC voltage? Some PLCs can operate within a range of AC voltages and even on 24-volt direct current. One of the first decisions that need to be made, if your PLC will be powered by 120-volt or 240-volt AC. Most industrial application PLCs will accept either, but you will want to be sure. Most power supplies come embedded in the processor, where others are housed in a separate module outside of the PLC casing, or hardwired to the processor.
  2. Speed: Does the system run fast enough to meet my application’s requirements? Like personal computers, PLCs possess varying processing speeds based on their operating memories, microchip capacities, and other factors. How fast your PLC needs to operate will depend on the number, precision, and power required by downstream machinery and devices. Here are a couple of things to consider when deciding on the needed PLC speed for your application:
    1. Number of inputs and outputs the PLC will control
    2. Number of time-critical events in the process
    3. Operating time for component or process
    4. Preciseness of component response when triggered
    5. Total cycle time required to collect and process inputs and issue output instructions
    6. Type, format, and complexity of the program and instructions powering it
  3. Input/Output Capacity: Will the PLC be able to manage the number of inputs and outputs that my application requires? Processes require PLCs that can manage and integrate all the data input and instruction output sources included in the operation. Often, both input and output data arrive as digital and analog packages, so you will want a PLC that can accept and deliver along either path.
  4. Communication: How am I going to communicate with my Programmable Logic Controller? Many times, the appropriate instructions an industrial PLC needs to send are based on inputs received from the operator. The way those instructions are transmitted must be compatible with the PLC, whether they are sent via LED, toggle switches, pushbuttons, touchscreens, or other interfaces.
  5. System Footprint: Will the system be located in one place or spread out over a large area? The speed and distance to be covered can be largely determined by how widespread the control network is. If all the input generators and output targets are confined in a relatively small space, there may be more PLC options available. If, however, the signals must travel over a larger area, it may need to contain a remote as well as the local I/O functionality. Designing processes from scratch may allow plants to avoid this complication, but established facilities with components already in place may be forced to use PLCs that can manage where they sit.

How is a PLC Programmed?

Programming a PLC is usually done on a computer and is then downloaded onto the controller. Most programming software offers Ladder Logic, or “C”. Ladder logic is the traditional programming language, mimicking circuit diagrams with “rungs” of logic read left to right. Each rung represents a specific action controlled by the PLC, starting with an input or series of inputs (contacts) that result in an output (coil). Due to its visual nature, Ladder Logic can be easier to implement than many other programming languages.