Filter Your Search

Category Group

Shop by Category

Search Results

Searching for: mersen
Viewing Page 5 of 942 (11,296 results)
250V 5A 1 1/2x13/32 MID TD

250V 5A 1 1/2x13/32 MID TD

Item #: TRM5

Brand: Mersen

Tri-Onic® TRM time-delay midget fuses are rated 250 volts AC and are offered in ampere ratings from 1/10 to 30A. They have 12 seconds time-delay at 200% rating to provide supplemental protection of small motors, small transformers and other high inrush loads, plus many other 250 volt applications. (Not for Branch Circuit Protection).

UL listed to standard 248-14 File E33925; CSA Certified to Standard C22.2 No. 248.14; 250VAC rating in all sizes up to 30A; Can be used with UltraSafeTM fuse holders; Numerous ratings for a wide variety of applications; 1 1/2” x 13/32” (10mm x 38mm) dimensions; Time-delay for circuits with high inrush currrent; Small transformers; Small motors; Lighting circuits; Control circuits

$13.49 /EA
NOT IN STOCK
SAFETY COVER FOR LARGE MPDB

SAFETY COVER FOR LARGE MPDB

Item #: MPDBC6869

Brand: Mersen

The Next Generation Power Distribution Block (PDB). Mersen power distribution blocks provide a safe and easy method of splicing cables, splitting primary power into secondary circuits and fulfilling requirements for fixed junction tap-off points. All blocks are UL and CSA approved while meeting spacing requirements for feeder and branch circuits in conjunction with UL508A and the National Electrical Code®. PDB options include single or dual conductor primary inputs and up to 30 secondary outputs. Specialty blocks are available allowing for up to 7 primary inputs. The MPDB series is offered in three size categories miniature (MPDB62 and MPDB63 series), intermediate (MPDB66 and MPDB67 series), and large (MPDB68 and MPDB69 series), in both aluminum and copper.

CSA Certified Class 6228 01; UL Listed to subject 1953, File E352417 unless noted otherwise

$24.53 /EA
NOT IN STOCK
250V 20A 1 1/2x13/32 MID TD

250V 20A 1 1/2x13/32 MID TD

Item #: TRM20

Brand: Mersen

Tri-Onic® TRM time-delay midget fuses are rated 250 volts AC and are offered in ampere ratings from 1/10 to 30A. They have 12 seconds time-delay at 200% rating to provide supplemental protection of small motors, small transformers and other high inrush loads, plus many other 250 volt applications. (Not for Branch Circuit Protection).

UL listed to standard 248-14 File E33925; CSA Certified to Standard C22.2 No. 248.14; Control circuits; Small motors; Small transformers; Lighting circuits; Can be used with UltraSafeTM fuse holders; Time-delay for circuits with high inrush currrent; Numerous ratings for a wide variety of applications; 250VAC rating in all sizes up to 30A; 1 1/2” x 13/32” (10mm x 38mm) dimensions

$16.47 /EA
NOT IN STOCK
600V 30A 2P CC ULTSFE W/IND

600V 30A 2P CC ULTSFE W/IND

Item #: USCC2I

Brand: Mersen

Mersen UltraSafe Modular Fuse holders introduce a new level of safety for Class CC (USCC) and Midget 1-1/2" x 13/32" (USM) AC and DC rated fuses up to 30 amperes. UltraSafe holders qualify as “Fingersafe” under IEC and DIN standards to an IP20 grade of protection, including fuse changing (with the flick of a finger). UltraSafe holders are available in 1, 2, 3 or 4 poles, with or without visual blown-fuse indicators in each pole. Multi-pole units can also be field assembled by ordering pin-tie handles. UltraSafe holders save up to 15% mounting space and any combination can be snapped onto 35mm DIN-rail for extra savings in panel building time. UltraSafe holders with Class CC fuses chosen for Type “2” No Damage protection give one of the safest protection packages in the industry. UltraSafe body material is tough and durable polyamide, with exceptional insulating properties.

IP20 Finger-Safe (touch safe); ATM, DCT, ATMR recommended for DC applications; Quick, tool-free, easy fuse change outs; Optional visual blown fuse Indicator lights; Compact footprint; DIN-rail mounting; CSA Certified C22.2; UL Listed to Standard 4248- 4 (class CC) and 4248-1 (midget), File E52283; IEC 60269-2-1 and 60947-3 Compliant (USM only); UL Listed to standard 4248-18 (photovoltaic), File E347822

$93.55 /EA
NOT IN STOCK
CC TD FUSE 600V 1A ATDR

CC TD FUSE 600V 1A ATDR

Item #: ATDR1

Brand: Mersen

Amp-Trap 2000 time-delay ATDR small-dimension fuses provide IEC Type 2 "no damage" protection to your facility's increasingly sensitive branch circuit components and small motors - minimizing the risk of fault-related damage. ATDR Class CC fuses deliver the best time-delay characteristics in their class with excellent cycling ability for small motor loads.

Branch circuit protection; Lighting, heating & general loads; Small motors; Contactors; DC listed to UL standard 248; UL listed to standard 248-4 File E2137; CSA certified to standard C22.2 No. 248.4; Highly current-limiting for low peak let-thru current; Metal-embossed date and catalog number for traceability and lasting identification; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Time-delay for motor starting inrush currents without nuisance opening; Improved cycling ability for frequent motor starts/stops without nuisance fuse opening; High-visibility orange label ensures instant brand recognition, simplifies replacement; High-grade silica filler ensures fast arc quenching and optimum current-limitation; Fiberglass body provides dimensional stability in harsh industrial settings

$42.71 /EA
IN STOCK

CC TD FUSE 600V 6A ATQR

Item #: ATQR6

Brand: Mersen

ATQR small-dimension fuses feature time-delay characteristics ideally suited for the high inrush currents of control transformers, solenoids, and similar inductive loads. Mersen's Amp-Trap 2000 ATQR fuses provide superior protection for the branch circuits of electrical distribution systems

CSA certified to standard C22.2 No. 248.4; DC listed to UL standard 248; UL listed to standard 248-4 File E2137; Lighting, heating & general-purpose loads; Inductive loads; Control transformers; Solenoids; Highly current-limiting for low peak let-thru current; High-grade silica filler ensures fast arc quenching and high current limitation; Fiberglass body provides dimensional stability in harsh industrial settings; Time-delay for control transformer inrush loads without nuisance opening; High visibility orange label ensures instant brand recognition, and simplifies replacement; Metal-embossed date and catalog number for traceability and lasting identification; Rejection-style design prevents replacement errors (when used with recommended fuse blocks)

$53.67 /EA
IN STOCK

CC TD FUSE 600V 1-1/2A ATQR

Item #: ATQR1-1/2

Brand: Mersen

ATQR small-dimension fuses feature time-delay characteristics ideally suited for the high inrush currents of control transformers, solenoids, and similar inductive loads. Mersen's Amp-Trap 2000 ATQR fuses provide superior protection for the branch circuits of electrical distribution systems

Highly current-limiting for low peak let-thru current; High-grade silica filler ensures fast arc quenching and high current limitation; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High visibility orange label ensures instant brand recognition, and simplifies replacement; Time-delay for control transformer inrush loads without nuisance opening; Fiberglass body provides dimensional stability in harsh industrial settings; Metal-embossed date and catalog number for traceability and lasting identification; Inductive loads; Control transformers; Lighting, heating & general-purpose loads; Solenoids; CSA certified to standard C22.2 No. 248.4; DC listed to UL standard 248; UL listed to standard 248-4 File E2137

$41.92 /EA
IN STOCK
CC TD FUSE 600V 30A ATDR

CC TD FUSE 600V 30A ATDR

Item #: ATDR30

Brand: Mersen

Amp-Trap 2000 time-delay ATDR small-dimension fuses provide IEC Type 2 "no damage" protection to your facility's increasingly sensitive branch circuit components and small motors - minimizing the risk of fault-related damage. ATDR Class CC fuses deliver the best time-delay characteristics in their class with excellent cycling ability for small motor loads.

CSA certified to standard C22.2 No. 248.4; DC listed to UL standard 248; UL listed to standard 248-4 File E2137; Branch circuit protection; Contactors; Lighting, heating & general loads; Small motors; High-visibility orange label ensures instant brand recognition, simplifies replacement; High-grade silica filler ensures fast arc quenching and optimum current-limitation; Improved cycling ability for frequent motor starts/stops without nuisance fuse opening; Time-delay for motor starting inrush currents without nuisance opening; Highly current-limiting for low peak let-thru current; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Metal-embossed date and catalog number for traceability and lasting identification; Fiberglass body provides dimensional stability in harsh industrial settings

$42.71 /EA
IN STOCK
PWR DIS BLK AL MINI 175A 3P 4

PWR DIS BLK AL MINI 175A 3P 4

Item #: MPDB63133

Brand: Mersen

The Next Generation Power Distribution Block (PDB). Mersen power distribution blocks provide a safe and easy method of splicing cables, splitting primary power into secondary circuits and fulfilling requirements for fixed junction tap-off points. All blocks are UL and CSA approved while meeting spacing requirements for feeder and branch circuits in conjunction with UL508A and the National Electrical Code®. PDB options include single or dual conductor primary inputs and up to 30 secondary outputs. Specialty blocks are available allowing for up to 7 primary inputs. The MPDB series is offered in three size categories miniature (MPDB62 and MPDB63 series), intermediate (MPDB66 and MPDB67 series), and large (MPDB68 and MPDB69 series), in both aluminum and copper.

CSA Certified Class 6228 01; UL Listed to subject 1953, File E352417 unless noted otherwise

$92.76 /EA
IN STOCK
MOV FUSE 600V SR70KA-2

MOV FUSE 600V SR70KA-2

Item #: VSP70-2

Brand: Mersen

Mersen surge suppression fuses are specially designed to address the protection of SPD systems. Our surge suppression fuses have been specially designed to withstand 8/20 µSec surge pulses without opening, allowing the SPD system to react to the surge. All surge suppression fuses have a 8/20 µSec surge rating, not a continuous current rating. Under AC short circuit conditions these surge suppression fuses are very current limiting.

ANSI/UL 248 Special Purpose MOV Fuse, File E60314; Various mounting configurations ferrules, blade, bolt-in, PC board mount; Surge ratings of 5-100kA 8/20 µSec capacity; VSP fuses rated 600VAC, 200kA I.R.

$48.16 /EA
IN STOCK
94684-FUSE,FORM 101

94684-FUSE,FORM 101

Item #: A70QS450-4

Brand: Mersen

A70QS Amp-Trap® high speed fuses were developed in response to the need for improved overall performance of 700V semiconductor fuses for new equipment requirements. A70QS fuses have lower I2t for better protection, longer life when subjected to cyclic loading, plus lower watts loss. A70QS is the best choice to protect dynamic solid state equipment such as motor drives, UPS, etc.

Low watts loss for cooler operation; Superior cycling ability for long, reliable life on high cyclic loading; 700V AC/DC rating gives greater design versatility; Ultra compact sizes allow down-sizing of existing equipment; Very Low I2t for improved protection of equipment; CSA certified File LR 12636; UL recognized component, AC/DC UL file E60314; DC: tested to UL standard 198L parameters (35-800A); AC: guide no. JFHR2

$857.46 /EA
NOT IN STOCK
94689-FUSE,FORM 101

94689-FUSE,FORM 101

Item #: A70QS800-4

Brand: Mersen

A70QS Amp-Trap® high speed fuses were developed in response to the need for improved overall performance of 700V semiconductor fuses for new equipment requirements. A70QS fuses have lower I2t for better protection, longer life when subjected to cyclic loading, plus lower watts loss. A70QS is the best choice to protect dynamic solid state equipment such as motor drives, UPS, etc.

700V AC/DC rating gives greater design versatility; Ultra compact sizes allow down-sizing of existing equipment; Superior cycling ability for long, reliable life on high cyclic loading; Very Low I2t for improved protection of equipment; Low watts loss for cooler operation; AC: guide no. JFHR2; UL recognized component, AC/DC UL file E60314; CSA certified File LR 12636; DC: tested to UL standard 198L parameters (35-800A)

$1,047.08 /EA
NOT IN STOCK
View Page:   « PREV 1 2 3 4 5 6 7 8 9 10 11 NEXT »